Please note, some Hexing HXE130s and HXP100DII meters, on internal hexing modem and hexing IDIS Concentrator, doesn't want you to log in to the meter, so then you need to check this tick box (and restart the meter):
it looks like the DC or modem already log in to them, and then if we do too, it messes up the permissions
At first we found that with xxx's HXE130, now we found it on yyy's? HXP100DII through the IDIS concentrator.
(the way we managed to figure that out is with a bridge to the Hexing HES, that Gift from Hexing helped me with.
I had to go in to Hexing, and sit there in a room with Gift, and get it up and going)
the way it goes wrong, that seems to indicate this problem, is that when we try to GET the serial number of the meter, it fails
C0 01 C1 00 01 00 00 60 01 00 FF 02 00
returns
C4 01 41 01 0B
instead of?
C4 01 41 00 0A 0B 31 34 34 36 31 36 38 34 31 39 34